CADETProcess.processModel.TubularReactor.set_diameter_from_interstitial_velicity#
- TubularReactor.set_diameter_from_interstitial_velicity(Q, u0)#
Set diamter from flow rate and interstitial velocity.
In literature, often only the interstitial velocity is given. This method, the diameter / cross section area can be inferred from the flow rate, velocity, and porosity.
- Parameters:
- Qfloat
Volumetric flow rate.
- u0float
Interstitial velocity.
Notes
Needs to be overwritten depending on the model porosities!